r&s®smw-九游官网下载
- 概览
- features & benefits
one intuitive software platform
-
- r&s®pulse sequencer software gui.
the r&s®pulse sequencer software is used to generate signal. the signal can be stored on the local hard disk or can be transmitted directly to the assigned signal generator if the required software option is installed on the signal generator.
the r&s®pulse sequencer software has an intuitive and clearly structured graphical user interface. the menu bar in the gui includes all the commonly used drop down menus with settings for working with the software. the toolbar gives users quick access to a new or to existing repositories for maintaining and managing them. a wizard helps the users to quickly configure signals by automatically going to all the dialogs necessary. on the left side of the gui, users have access to all the items needed to set-up the scenario, such as defined pulses, sequences and-, inter-pulse modulation profiles. the main screen shows the configured scenario and includes all the details for generating the signal.
repository tree with configured content
- r&s®pulse sequencer repository tree
in the repository tree, all the configured items (scenarios, sequences, pulses, etc.) are stored and become visible after they have been expanded. each item can be reused in different scenarios. in addition, the configured signal generator(s) to be used for waveform generation are listed here.
block diagram for signal generation
-
- block diagram in the r&s®pulse sequencer software gui.
the block diagram gives an overview of the full signal generation chain. the signal configuration, waveform generation and instrument assignment can be directly accessed via the block diagram. the generated waveform can be transmitted directly to the assigned signal generator and stored in the repository. once a waveform is stored in the repository, it can be loaded from the repository and sent to the assigned signal generator without running through a new waveform generation process. the user also has the choice to save the waveform intentionally on a hard disk or usb device instead of transmitting the waveform directly to a signal generator.
application: pulse configuration
-
- pulse configuration dialog.
the pulse configuration dialog gives users access to all the pulse parameters. they can configure parameters such as timing, level and modulation on pulse. in addition, marker signals related to the pulse timing parameters can be configured. after configuration of the pulse, a preview gives quick access to a graphical representation of the selected modulation scheme or also to the envelope of the pulse. as a result, a configured pulse’s i/q data, phase or frequency can be viewed. the envelope tab lets users preview parameters such as defined droop, rise/fall time or ripple of the pulse.
application: configuration of pulse trains
-
- pulse train and waveform in sequencer tool.
the r&s®smw-k300 option enables a sequencing editor that lets users configure pulse repetitions with internally generated pulses or repetition of loaded customer waveforms. the sequence of the signals is defined in an editor and is automatically displayed in a block diagram so that the configured sequence can be easily cross-checked. sequencing items can be configured pulses or waveforms. the waveform according to the configured signal is then calculated either as a single waveform or as a multi-segment waveform. for waveforms, no inter pulse modulation is possible.