this application note presents means to integrate r&s test and measurement instruments into the agilent® ads® design system. methods to include r&s instruments are presented, accompanied by a free-of-charge software solution which is provided with this application note. it makes it very easy to include r&s instruments into your ads environment and your design flow. versions for both windows xp® and linux® operating systems are available.
使用不同的功率电平、频率偏置、扫描跨度和扫描方向,可以控制两个内部源(使用四端口仪器)以及多个外部源(通过 gpib 或 lan 接口连接到 r&s®zva)。 r&s®zva 可以控制所有的罗德与施瓦茨信号源,以及其他供应商提供的所有与 scpii 兼容的信号源。这使得 r&s®zva 成为放大器以及混频器特性测量时的理想选择。第二个内部源可用作 lo,以便在混频器上进行快速的扫描变频损耗测量,或者提供第二个信号音以便在放大器和混频器上进行快速的交调测量。只需在测试端口配置表中输入几项,即可完成交调测量的设置。
如果已经另行安装 r&s®zvaxx-b16 直接发生器/接收机接入选件,则 r&s®zva 可以使用脉冲发生器或脉冲调制器执行脉冲测量。r&s®zva-k7 以及 r&s®zva-b7 选件功能相同,唯一的不同在于,r&s®zva-k7 在每次扫描时最长记录时间为 3 ms,r&s zva-b7 为 25 ms。r&s®zva-k7 可与所有的 r&s®zva 以及 r&s®zvt 型号一起使用,而不论测试端口的数量。
如果已经另行安装 r&s®zvaxx-b16 直接发生器/接收机接入选件,则 r&s®zva 可以使用脉冲发生器或脉冲调制器执行脉冲测量。r&s®zva-k7 以及 r&s®zva-b7 选件功能相同,唯一的不同在于,r&s®zva-k7 在每次扫描时最长记录时间为 3 ms,r&s zva-b7 为 25 ms。r&s®zva-k7 可与所有的 r&s®zva 以及 r&s®zvt 型号一起使用,而不论测试端口的数量。
provides information on security issues when working with r&s®zva in secure areas.
provides the information required to prepare the instrument for use and start working.basic operations and handling are described.
the r&s®zva series is the high-end class of the rohde & schwarz network analyzers. it combines operating ease and high measurement speed, uniformly implemented in the r&s®zva, r&s®zvb and r&s®zvt, with exceptional rf characteristics, a wide scope of functions and high flexibility.
provides the information required to prepare the instrument for use and start working.basic operations and handling are described.
this document describes how the advanced calibration techniques of the zva vector network analyzers can solve the challenges of measuring the s-parameters on impedance matching devices. the document describes the concept and setup required to perform the calibration of the zva and making the measurement. the procedure described in this application note applies to the zvb and zvt vector network analyzers as well.
50 ghz 至 75 ghz (r&s®zva-z75)60 ghz 至 90 ghz (r&s®zva-z90)75 ghz 至 110 ghz (r&s®zva-z110/r&s®zva-z110e)使用 r&s®zva24、r&s®zva40、r&s®zva50、r&s®zva67 或 r&s®zvt20 网络分析仪r&s®zva-z75:> 90 db,典型值为 110 dbr&s®zva-z90:> 100 db,典型值为 115 dbr&s®zva-z110:> 100 db,典型值为 110 dbr&s®zva-z110e:> 95 db,典型值为 110 db罗德与施瓦茨变频器的典型输出功率:典型值为 4 dbm (r&s®zva-z75)典型值为 10 dbm (r&s®zva-z90)典型值为 10 dbm (r&s®zva-z110)借助 r&s®zva-z75